centrifugal pump start up procedure|pump installation checklist pdf : dealers Jul 27, 2020 · Do pump priming by opening the vent valve and to release the air, when liquid starts oozing out of the vent then close the vent valve. Rotate the shaft by hand to see if it is moving freely or not. Check if the pump is rotating … Priming is the operation in which the suction pipe, casing of the pump, and a portion of the pipe up to the delivery valve are filled up from an outside source with the liquid to be raised by the pump before starting the pump. Read Also: What is the function of Flow . See more
{plog:ftitle_list}
A brief comparison between two types of pumps, peripheral and classic centrifugal. What is different and what are the main features of both.Tempco website: h.
Aug 15, 2022 · Before starting up a centrifugal pump, follow this step-by-step checklist to ensure safety, minimize hazards, reduce maintenance costs, and improve pump reliability.
Centrifugal pumps convert energy of an electric motor or turbine into velocity or kinetic energy and then into pressure energy of the fluid being pumped. The energy changes occur around two main parts of the pump, impeller and volute
Starting Procedure of Centrifugal Pump
1. **Secure the Tag Number:** Before starting the centrifugal pump, ensure that the tag number of the pump is correctly recorded and identified. This will help in tracking maintenance records and troubleshooting in the future.
2. **Check Pump Alignment:** Verify that the pump is properly aligned with the motor and the piping system. Misalignment can lead to excessive vibration, premature wear, and reduced efficiency.
3. **Inspect Pump Components:** Check all pump components such as impeller, casing, shaft, and bearings for any signs of damage or wear. Replace any worn-out parts before starting the pump.
4. **Check Oil Levels:** If the pump is equipped with oil lubrication, ensure that the oil levels are adequate. Insufficient lubrication can lead to overheating and premature failure of the pump.
5. **Open Inlet Valve:** Slowly open the inlet valve of the pump to allow the fluid to fill the pump casing. This helps in priming the pump and prevents dry running.
6. **Start the Motor:** Once the pump is primed, start the motor gradually and monitor the pump performance. Ensure that the motor is running in the correct direction as per the pump rotation direction.
7. **Adjust Flow Rate:** Adjust the flow rate of the pump by controlling the discharge valve. Gradually increase the flow rate to the desired operating point while monitoring the pump performance.
8. **Monitor Pump Parameters:** Keep an eye on important pump parameters such as discharge pressure, flow rate, and motor current. Any abnormal readings should be investigated immediately.
Centrifugal Pump Installation Procedure
1. **Select a Suitable Location:** Choose a location for the centrifugal pump that is well-ventilated, easily accessible for maintenance, and away from any sources of vibration or heat.
2. **Foundation Preparation:** Ensure that the foundation for the pump is stable, level, and capable of supporting the weight of the pump and motor. Proper foundation preparation is essential for smooth pump operation.
3. **Piping Installation:** Install the suction and discharge piping according to the pump manufacturer's recommendations. Proper piping installation is crucial for efficient pump performance and longevity.
4. **Electrical Connections:** Make sure that the electrical connections for the pump motor are done by a qualified electrician following all safety standards and regulations.
5. **Alignment:** Align the pump and motor shafts using appropriate alignment tools to minimize vibration and ensure smooth operation.
6. **Priming:** Prime the pump by filling the pump casing with the fluid before starting the pump. Proper priming helps in preventing cavitation and ensures efficient pump operation.
Centrifugal Pump Commissioning Checklist
1. **Check Pump Rotation:** Verify that the pump is rotating in the correct direction as per the manufacturer's specifications.
2. **Check Sealing:** Inspect the pump seals for any leaks or damage. Replace any faulty seals to prevent fluid leakage and contamination.
3. **Monitor Vibration Levels:** Monitor the vibration levels of the pump during operation. Excessive vibration can indicate misalignment or other issues that need to be addressed.
4. **Verify Performance:** Test the pump performance by measuring parameters such as flow rate, pressure, and power consumption. Ensure that the pump is operating within the design specifications.
5. **Document Results:** Keep a detailed record of the commissioning process, including any adjustments made and performance measurements. This documentation can be useful for future reference and troubleshooting.
Before starting up a centrifugal pump, follow this step-by-step checklist to ensure safety, minimize hazards, reduce maintenance costs and improve pump reliability: Secure the tag number of the pump correctly to be …
To avoid cavitation in centrifugal pumps, the pressure of the fluid at all points within the pump must remain above saturation pressure. The quantity used to determine if the pressure of the liquid being pumped is adequate to avoid cavitation is the net positive suction head (NPSH).
centrifugal pump start up procedure|pump installation checklist pdf