As of today, some 20 vessels have these solutions fitted, all from 4 tanks 300m3 total, up to 16 tanks with 1.500m3 total capacity. . “after learning the process of how to handle f.ex. Drill Cuttings from rig-to-vessel-to-shore. it is now business as usual, as any other cargo aboard” . Typical pump capacity mud: 30-100 m3/h with .
{plog:ftitle_list}
KOSUN is a professional solids control equipment manufacturer in China.KOSUN can supply solids control equipments in drilling industry,such as:Black Rhinoceros shale shaker,Black Rhino 450 centrifuge,mud cleaner,desander,desilter,vacuum degasser,jet mud mixer,centrifugal pump,shear pump,submersible slurry pump,mud agitator,mud gun,etc.
On Nov 14, 2013, an important discussion took place regarding the impact of closing the discharge valve in a centrifugal pump while it is running. This issue is critical not only for centrifugal pumps but also for positive displacement (PD) pumps. In this article, we will delve into the various problems that can arise when the discharge valve is closed during operation, as well as the consequences of closing the valve when starting the pump.
>If you start the pump discharge valve closed, it means no discharge head minimum resistance to the pump and minimum current drawn. Even though current taken during startup is more than
Centrifugal Discharge Valve Closed
Centrifugal pumps rely on the principle of centrifugal force to move fluids through the system. When the discharge valve is closed while the pump is running, several issues can occur. One of the primary problems is the buildup of pressure within the pump and the associated increase in power consumption. The pump may struggle to maintain its flow rate, leading to inefficiencies and potential damage to the pump components.
Pump Discharge Valve Closed
In general, closing the discharge valve of a pump restricts the flow of fluid, causing back pressure to build up within the system. For centrifugal pumps, this can result in cavitation, a phenomenon where vapor bubbles form due to low pressure regions in the pump. Cavitation can lead to erosion of the pump impeller and other components, reducing the pump's efficiency and lifespan.
Discharge Valve Closed When Starting Pump
Closing the discharge valve when starting a pump can also have detrimental effects. When the pump is started with the discharge valve closed, the pump may experience a sudden surge in pressure, causing stress on the pump components. This can lead to mechanical failures, including seal damage and bearing wear. Additionally, the motor driving the pump may draw excessive current, leading to overheating and potential burnout.
Please explain what are all the problems that pump will encounter if the discharge valve is closed in the running condition for both centrifugal and PD pumps. In case of …